All-Flex®

Multipurpose Power Cable

Direct’s All-Flex® is a highly versatile multipurpose power cable designed for internal/external applications, including uninterruptible power supplies (UPS), transformers, controls, battery chargers, leads and extensions, and wet environments. All-Flex is UL and cRUus listed, CSA approved, RoHS compliant, for CT use (1/0 and larger sizes), and manufactured in the USA.

  • Rope-lay, bunch-stranded 30 AWG copper conductor
  • Bare or tinned ASTM Class K copper
  • Jacketed with high-quality PVC compound
  • CMRT and Prop 65 Compliant

Specifications

Conductors
  • Rope-lay, bunch-stranded 30 AWG copper conductor
  • Intermediate copper standing available
  • Bare or tinned ASTM Class K copper
Voltage Rating
  • 600 V; AWM Style 10269 — 1,000 V
Insulation & Jacket
  • Insulated/Jacketed with high-quality PVC compound
Resistance Properties
  • Resistant to battery acid, crushing force, diesel fuel, engine coolant, engine oil, ethanol, extreme temperatures, flame, gasoline, power-steering fluid, and transmission fluid
  • UL tested 720 hours sunlight resistance rating
  • UL tested 60°C (140°F) oil resistant temperature rating
Temperature Range
  • Enhanced Temperature Rating
  • -50°C (-58°F) to 105°C (221°F) Dry; 75°C (167°F) Wet
Industry Approvals
  • UL 758 (AWM Styles 1232, 1283, 1284, 1337, 1338, 1339, 1581, 2556, 10070, and 10269)
  • UL 83 (THW, TW75, and THHW)
  • UL 1063 (MTW)
  • UL 1426 (BC5W2)
  • UL 1581 and UL 2556
  • CSA C22.2 No. 75 (TW75), CSA C22.2 No. 127 (TEW), and CSA C22.2 No. 210 (AWM)
  • CSA C22.2 No. 2556
  • cRUus Recognized
  • ASTM B49, B3 or B33, and B172
  • SAE J1127 Type SGT
  • NEC (NFPA 70)
  • CEC (CSA C22.1)
  • ABYC E-11 (AC/DC - Electrical Boat Systems)
  • 33-CFR-Subchapter S
  • FT-1, FT-2, FT-4, and VW-1
  • For CT USE (1/0 AWG and Larger)
  • -40°C to 105°C Operating Temp Rating
  • 75°C Wet Temp Rating (Water-Res)
  • 60°C Oil Temp Rating (Oil-Res)
  • 720 Hour UV Rating (Sun-Res)
  • CMRT and Prop 65
Available Lengths
  • Reels at 250’ / 500’ / 1,000’ / 2,500’
  • Coils at 25’ / 50’ / 100’
  • Custom lengths available upon request
Cable SizeStranding GaugeConductor
Stranding
Insulation Thickness
(Nominal)
Outside Diameter
(Nominal)
Cable Weight
(per 1,000')
Ampacity*
ininlbs
#830182.060.2707780 A
#630273.060.315111105 A
#430429.060.350164140 A
#330533.060.377206165 A
#230676.060.419247190 A
#130845.080.490320220 A
1/0301,066.080.530392260 A
2/0301,339.080.579485300 A
3/0301,677.080.632596350 A
4/0302,109.080.695741405 A
250 MCM302,527.100.793916455 A
350 MCM303,478.100.9151,242570 A
500 MCM305,054.1001.1301,815700 A
(*) Allowable ampacity per NFPA 70 / NEC Article 310. Values are based on ambient temperature of 30°C.
Cable SizeStranding GaugeConductor
Stranding
Insulation Thickness
(Nominal)
Outside Diameter
(Nominal)
Cable Weight
(per 1,000')
Ampacity*
AWG or MCMmmmmkg
#8301821.52 6.863580 A
#6302731.52 8.0050105 A
#4304291.528.8974140 A
#3305331.52 9.5793165 A
#2306761.52 10.64112190 A
#1308452.0312.45145220 A
1/0301,0662.0313.46178260 A
2/0301,3392.0314.71220300 A
3/0301,6772.0316.05270350 A
4/0302,1092.0317.65336405 A
250 MCM302,5272.5420.14415455 A
350 MCM303,4782.5423.24563570 A
500 MCM305,0542.5428.70823700 A
(*) Allowable ampacity per NFPA 70 / NEC Article 310. Values are based on ambient temperature of 30°C.
Jacket Colors
  • Black (Standard) Red
Marking Options
  • Quick Print®
  • Surface Print
  • Indent Print
  • Logo / Icons / Branding
  • Sequential Marking